18L Table Top Dental Steam Sterilizer | Oxyaider Medical Supply

Product categories

18L Table Top Dental Steam Sterilizer Autoclave | TR250N

18L Table Top Dental Steam Sterilizer Autoclave | TR250N

R20,000.00

  • Pressure adjustment: adjust the inter pressure, if over standard value automatic vent
  • Please pay attention to correct voltage and frequency.
  • Please close steam emissions switch.Before In the disinfection.
  • Before each use.Must supply water 800ml。(Distilled water is the bast).
  • Do not use any corrosive or chemical water as the disinfection.

IN STOCK At Supplier , Delivery Is Estimated 10 – 15 Working Days

Available on backorder

Qty:
Compare

Description

18L Table Top Dental Steam Sterilizer Autoclave

SPECIFICATION

 

Sterilization Class CLASS N
Sterilizing Temperature 122℃ / 251.6℉ & 132℃ / 269.6℉
Chamber Dimension Ø250 x D350mm / Ø9.84″ x D13.78″
Display High-light LED tube display
Input 110V, 60HZ, 900VA
Control Precision Temperature: 1℃ / 33.8℉
Pressure: 0.1bar
Safety System Relief valve
Hand lock door
Pressure or temperature over load protection
Alarm system
Tray Holder 3 layers tray
Chamber Medical stainless steel 304
Max working pressure:2.3bar
Min working pressure: -0.9bar
Max temperature: 145℃ / 293℉
Dimension 56cm x 39cm x 36cm / 22″ x 15″ x 14″
Weight 25kgs / 55lbs
Operation Temperature 5~40℃ / 41℉~104℉
Noise <50db

 

PROGRAM

PROGRAM Temp. Pressure Sterilization Time
134℃/  273.2℉ 2.2bar 5mins
121℃ / 249.8℉ 1.2bar 25mins

Application Field

Dental Clinic, Hospital, First-aid Station, Laboratory, Veterinary hospital, Beauty Parlor, Tattoo House…

Quality System

 

Quality System No. Quality System Name
ISO 9001 Quality management systems—Requirements
ISO 13485 Medical device-Quality management systems-Requirement for regulatory purposes

 



Certification

ISO 9001
Steam Sterilizer CE
Sterilizer Chamber CE

Application Directive and Standard

 

Directive or Standard No. Directive or Standard Name
MDD 93/42/EEC Medical Device Directive
PED 97/23/EC Pressure Equipment Directive
EN 61010-1 Safety regulations for electrical measuring, controlling and laboratory Devices- Part 1: General requirements
EN 61010-2-040: Safety requirements for electrical equipment for measurement, control and laboratory use —Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
EN 13060 Small steam sterilizers
EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements
Product Information

Technical Detail

Model

 

TR250N Basic model
Chamber capacity Ø250XD350mm / Ø9.84″ x D13.78″
Inside capacity 18 Liter
Outside size (L x W x H)CM 56 x 39 x 36CM / 22″ x 15″ x 14″
Packing Size (L x W x H)CM 63 x 46 x 41CM / 25″ x 18″ x 16″

N.W:25KGS / 55lbs; G.W: 26KGS / 57lbs

Sterilize temperature 122℃& 134℃
Sterilize pressure(Mpa) 0.12Mpa & 0.22Mpa
Sterilize time 25Min& 6Min
Hearter 900W
Material quality Stainless steel #304. Boiler chamber surface with burnish.
Suface deal with The machine foundation and the shell use high temperature baking varnish processing
Electric current-110V 8A
Safety equipment *Pressure adjustment:adjust the inter pressure.If over standard value automatic vent.

*Avoid overheat protect device:When inter temperature overheat,power break electric

current automatically.

Disinfection complete action Automatic discharge of water and steam

Additional Information

ADVANTAGE

1. It has an normal open valve to release air  pressure  automatic.

2. This autoclave will drain water automatic after every cycle.

3. Water level sensor can effectively avoid the heater burned.

4. The digital display can show temperature instantly.

5. Error code alarm system can make users judging problem easily.